热门搜索:

上海楹点检测设备有限公司提供的无损检测仪器设备包括:超声检测(UT);射线检测(RT);渗透检测(PT);磁粉检测(MT);涡流检测(ET);化学用品(CH)、超声波相控阵、超声波测厚仪、超声导波、超声TOFD探伤仪、超声波探头、涡流探伤仪、涡流探头、涡流阵列、磁粉探伤机。代理以下品牌:汕超、美国GE(德国KK)、奥林巴斯(Olympus NDT)、美国磁通(Magnaflux)、DAKOTA等;

    索耐MPI-502多功能电气测试仪
    • 索耐MPI-502多功能电气测试仪

    索耐MPI-502多功能电气测试仪

    更新时间:2025-04-10   浏览数:976
    所属行业:仪器仪表 无损检测仪器 探伤仪
    发货地址:上海市宝山区  
    产品规格:标准规格
    产品数量:0.00台
    包装说明:纸箱
    价格:面议
    产品规格标准规格包装说明纸箱

    索耐MPI-502多功能电气测试仪

    指数: 

    WMGBMPI502

    Multifunction Electrical Installations Meter

    Short circuit loop parameters measurements:

    ?measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45...65 Hz,

    ?measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.

    Testing the RCD breakers of AC, A types:

    索耐MPI-502多功能电气测试仪?testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,

    ?IA measurement

    ?RE and UB measurement without tripping the circuit breaker,

    ?extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.

    Detection of the replacement L and N in the socket and automatic conversion in the meter.

    Low voltage resistance measurements of protective circuits and junctions:

    ?measurement of resistance with ±200 mA current

    ?calibration of test leads - possibility of using any length of test leads,

    ?low current resistance measurement with accoustic **ling

    Rapid check for the correct connection of PE wire using touch electrode.

    Measurement of mains voltage and frequency.

    Power supply from LR6 batteries or NiMH accumulators (option).

    The device meets the requirements of IEC 61557 standard.

    MPI-502 is equipment to perform complete test and verify on electrical installations according to the most common safety standards (IEC 61557, VDE 0100, BS7671).

    Short circuit loop impedance measurement ZL-PE, ZL-N, ZL-L

     索耐MPI-502多功能电气测试仪

    Measurment using 7,6/13,3 A current – Measurement range according to

    IEC 61557: 0,13...1999 Ω

    (for 1,2 m lead) and 0,19...1999 Ω (for WS-01 and WS-04).

     索耐MPI-502多功能电气测试仪

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(5% m.v. + 3 dgt)

    20,0...199,9 Ω    0,1 Ω    

    200...1999 Ω    1 Ω    

    ?Nominal work voltage: UnL-N/ UnL-L: 220/380 V, 230/400 V, 240/415 V,

    ?Voltage operating range: 100…264 V (for ZL-PE i ZL-N) and 100…440 V (for ZL-L),

    ?Nominal network frequency fn: 50 Hz, 60 Hz,

    ?Max. test current: 23 A (230 V), 44 A (440 V),

    ?PE terminal connection corectores check with the help of touch electrode

    Readings of fault loop impedance R and fault loop reactance XL

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(5% m.v. + 5 digits) of ZS value

    20,0...199,9 Ω    0,1 Ω    

    calculated and displayed for ZS<200 Ω.

    Short circuit loop impedance ZL-PE in mode RCD – without RCD tripping 

    Measurement using <15 mA,current measurement range in accordance with IEC 61557: 0,51...1999,9 Ω

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(6% m.v. + 10 dgt)

    20,0...199,9 Ω    0,1 Ω    ±(6% m.v. + 5 dgt)

    200...1999 Ω    1 Ω    

    ?test without tripping the RCD for IΔn ≥ 30 mA,

    ?nominal work voltage: Un: 220 V, 230 V, 240 V,

    ?voltage operating range:180...270 V,

    ?frequency operating range fn: 50 Hz, 60 Hz

    ?PE terminal connection correctness check with the help of touch electrode

    Readings of fault loop impedance R and fault loop reactance XL (without tripping the RCD)

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(6% m.v + 10 dgt) of ZS value

    20,0...199,9 Ω    0,1 Ω    ±(6% m.v + 5 dgt) of ZS value

    ?calculated and displayed for ZS<200 Ω.

    RCD parameters test (voltage range 180...270 V):

    RCD tripping test and measurment of tripping time tA (for tA function)

    Breaker Type    Test Current

    Multiplier    Range    Resolution    Accuracy

    Standard    0,5*IΔn    0...300 ms    1 ms    ± (2% m.v. + 2 dgt)

     

        1*IΔn            

        2*IΔn    0...150 ms        

        5*IΔn    0...40 ms        

    Selective    0,5*IΔn    0...500 ms        

        1*IΔn            

        2*IΔn    0...200 ms        

        5*IΔn    0...150 ms        

    ?Precision of the differential current: 0,5*IΔn:-8...0% for 1*IΔn, 2*IΔn, 5*IΔn: 0...8%

    Voltage measurement

    Range    Range    Accuracy

    0,0 V...299,99 V    0,1 V    ±(2% m.v. + 6 dgt)

    300 V...500 V    1 V    ±(2% m.v + 2 dgt)

    Frequency measurement

    Range    Range    Accuracy

    45,0 V...65,0 Hz    0,1 Hz    ±(1% m.v. + 1 dgt)

     

    Touch voltage measurement referred to the rated residual current (UB)

    Range    Resolution    Test

    Current    Accuracy

    0..9,9 V    0,1 V    0,4 x IΔn    10% m.v. ± 5 dgt

    10,0..99,9 V            0...15% m.v.

    Measurementof the RCD disconection current IA for sine waveform testing current

    Selected

    Current    Range    Resolution    Test

    Current    Accuracy

    10 mA    3,3...10,0 mA    0,1 mA    0,3 x IΔn...1,0 x IΔn    ±5%IΔn

    30 mA    9,0...30,0 mA            

    100 mA    33...100 mA    1 mA        

    300 mA    90...300 mA            

    500 mA    150...500 mA            

    ?It is posible to start the measurement from the positive or negative half of the forced leaking current

    RCD IA tripping current measurement for unidirectional pulsating residual current

    Selected

    Current    Range    Resolution    Test

    Current    Accuracy

    10 mA    4...20,0 mA    0,1 mA    0,35xIΔn..2,0xIΔn    ±10%IΔn

    30 mA    12,0...42,0 mA        0,35xIΔn..1,4xIΔn    

    100 mA    40,0...140 mA    1 mA        

    300 mA    120...420 mA            

    ?Measurement is possible for a positive or negative forced leakage current.

    Low voltage test of the circuit and insulation continuity

    Measurement range in accordance with IEC61557:0,12...400 Ω

    Test of PE wire continuity using a ±200 mA current

    Range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(2% m.v + 3 dgt)

    20,0...199,9 Ω    0,1 Ω    

    200...400 Ω    1 Ω    

    ?Voltage on open terminals: 4…9 V,

    ?Test current at R<2 Ω: min. 200 mA,

    ?Autocalibration of test leads

    ?Measurements for both polarizations of the current

    The device meets the requirements of EMC standards EN 61326 - 1:2006 and EN 61326 - 2-2:2006.

    Electric safety:

    ?type of insulation: double, according to EN 61010 - 1 and IEC 61557

    ?measurement category: IV 300 V (III 600 V) according to EN 61010 - 1

    ?protection class acc. to EN 60529: IP67

    Other technical data:

    ?dimentions: 220 x 98 x 58 mm

    ?weight: ~1 kg

    ?Auto OFF time: 300, 600, 900 second

    ?number of measurements Z and RCD (for NiMH batteries): >5000 (2 per minute)

    ?m.v.” measured value.