热门搜索:

上海楹点检测设备有限公司提供的无损检测仪器设备包括:超声检测(UT);射线检测(RT);渗透检测(PT);磁粉检测(MT);涡流检测(ET);化学用品(CH)、超声波相控阵、超声波测厚仪、超声导波、超声TOFD探伤仪、超声波探头、涡流探伤仪、涡流探头、涡流阵列、磁粉探伤机。代理以下品牌:汕超、美国GE(德国KK)、奥林巴斯(Olympus NDT)、美国磁通(Magnaflux)、DAKOTA等;

    MPI-505电气安装测试仪
    • MPI-505电气安装测试仪

    MPI-505电气安装测试仪

    更新时间:2024-11-16   浏览数:1003
    所属行业:仪器仪表 无损检测仪器 探伤仪
    发货地址:上海市宝山区  
    产品规格:标准规格
    产品数量:0.00台
    包装说明:纸箱
    价格:面议
    产品规格标准规格包装说明纸箱

    MPI-505电气安装测试仪

    上海楹点检测设备有限公司产品和服务质量好,性价比高,为您节省采购成本!电子测量仪器:示波器,示波表,电源,频谱仪,温度测试仪,数字电桥,万用表,频闪仪,转速表,功率计,信号发生器,钳形表,电阻测试仪,绝缘电阻测试仪,兆欧表,热像仪........公司承诺,所有商品保证原装正品,一年保修,终身维护!服务热线:151-210-77168/Q

    ?

    指数: 

    WMGBMPI505

    Multifunction Electrical Installations Meter

    Measurement of short-circuit loop parameters:

    ?in L-PE, L-N, L-L circuits as well as in L-PE (RCD) circuits - without tripping RCD breakers of current 30 mA.

    ?impedance measurement of short-circuit loops in power networks of nominal voltages: 115/200 V, 220/380 V, 230/400 V, 240/415 V and frequencies in the range of 4565 Hz..

    Testing of AC and A types residual current circuit breakers:

    ?testing of regular and selective residual current circuit breakers of nominal differential currents: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000 mA,

    ?IA trip current measurement,

    ?tA trip time measurement for 0.5In, In, 2In, 5In,

    ?measurement of earth continuity and touch voltage without tripping RCDs,

    ?functionality of automatic measurement of residual current circuit breaker parameters.

    Measurement of insulation resistance at voltages: 100 V, 250 V, 500 V and 1000 V.

    Low-voltage measurement of resistance, protective connections and equipotential bonding:

    ?measurement of continuity of protective connections with current ±200 mA,

    ?automatic calibration of test leads - capability of using any test leads,

    ?measurement of resistance with low current and acoustic **ing.

    Quick verification of correctness of the PE wire connection with a touch probe.

    Measurement of AC voltage.

    Indication of phase sequence.

    Memory of 990 measurements, data transfer to a PC over the USB interface.

    MPI-505 is equipment to perform complete test and verify on electrical installations according to the most common safety standards (IEC 61557, VDE 0100, BS7671).

    Measurement of short-circuit loop impedance ZL-PE, ZL-N, ZL-L

    Measurement range acc. to IEC 61557: 0.13...1999 Ω for a 1.2 m test lead:

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(5% m.v +3 digits)

    20,0...199,9 Ω    0,1 Ω    

    200...1999 Ω    1 Ω    

    ?Nominal operating voltage UnL-N/ UnL-L: 115/200 V, 220/380 V, 230/400 V, 240/415 V

    ?Operating voltage range: 100…264 V (for ZL-PE i ZL-N) and 100…440 V (for ZL-L)

    ?Nominal power network frequency fn: 50 Hz, 60 Hz

    ?Operating frequency range: 45…65 Hz

    ?Maximal measurement current: 23 A at 230 V (10 ms), 40 A at 400 V (10 ms),

    ?Verification of correctness of the PE terminal connection with a touch (for ZL-PE)

    Measurement of short-circuit loop impedance ZL-PE in the RCD mode 

    Measurement range acc. to IEC 61557: 0.5...1999 Ω for a 1.2 m test lead

    Display range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(6% m.v + 10 digits)

    20,0...199,9 Ω    0,1 Ω    ±(6% m.v + 5 digits)

    200...1999 Ω    1 Ω    

    ?Does not trip RCD breakers of RCD current IΔn ≥ 30 mA

    ?Nominal operating voltage Un: 115 V, 220 V, 230 V, 240 V

    ?Operating voltage range: 100…264 V

    ?Nominal power network frequency fn: 50 Hz, 60 Hz

    ?Operating frequency range: 45…65 Hz

    ?Verification of correctness of the PE terminal connection with a touch probe

     

    Measurement of insulation resistance

    Measurement range acc. to IEC 61557 - 2:

    ?for UN = 100 V: 100 kΩ...500 MΩ

    ?for UN = 250 V: 250 kΩ...1 GΩ

    ?for UN = 500 V: 500 kΩ...2 GΩ

    ?for UN = 1000 V: 1 MΩ...3 GΩ

     

    Display range*)    Resolution    Accuracy

    0...1999 kΩ    1 kΩ    ±(3% m.v. + 8 digits)

    2,00...19,99 MΩ    0,01 MΩ    

    20,0...199,9 MΩ    0,1 MΩ    

    200...500 MΩ    1 MΩ    

    200...1000 MΩ    1 MΩ    

    200...1999 MΩ    1 MΩ    

    2,00...3,00 GΩ    0,01 GΩ    ±(4% m.v. + 6 digits)

     

    *) not exceeding the measurement range for a given voltage.

    ?Measurement voltage: 100 V, 250 V, 500 V and 1000 V

    ?Detection of presence of voltage before the measurement

    ?Discharge of the measured object after the measurement

    ?Measurements of voltage on terminals +RISO, -RISO within the range of: 0…440 V

    ?Measurement current < 2 mA

    Low-voltage measurement of circuit continuity and resistance

    Measurement of protective conductor continuity with current ±200 mA

    Measurement range acc. to IEC 61557 - 4: 0.12...400 Ω

    Range    Resolution    Accuracy

    0,00...19,99 Ω    0,01 Ω    ±(2% m.v. + 3 digits)

    20,0...199,9 Ω    0,1 Ω    

    200...400 Ω    1 Ω    

    ?Voltage on open terminals: 4…9 V

    ?Output current at R<2 Ω: min. 200 mA

    ?Compensation of test lead resistance

    ?Measurements for both polarities of current

    Measurements of RCD breaker parameters (operating voltage range 100…264 V):

    RCD tripping test and measurement of tA trip time (for the tA measurement function)

    RCD type    Test current

    multiplier    Range    Resolution    Accuracy

    Standard    0,5*IΔn    0...300 ms    1 ms    ± (2% m.v. + 2 digits)

        1*IΔn            

        2*IΔn    0...150 ms        

        5*IΔn    0...40 ms        

    Selective    0,5*IΔn    0...500 ms        

        1*IΔn            

        2*IΔn    0...200 ms        

        5*IΔn    0...150 ms        

    *for IΔn= 10 mA and 0.5 IΔn uncertainty is + 2% m.v. + 3 digits

     

    Measurement of IA RCD trip current for sinusoidal differential current:

     

    Selected

    current    Measurement

    range    Resolution    Test

    current    Accuracy

    10 mA    3,3...10,0 mA    0,1 mA    0,3xIΔn...1,0xIΔn    ± 5% IΔn

    30 mA    9,0...30,0 mA            

    100 mA    33...100 mA    1 mA        

    300 mA    90...300 mA            

    500 mA    150...500 mA            

    1000 mA    330...1000 mA            

    ?Capability of starting the measurement from either positive or negative half-period of forced leakage current

    Measurement of IA RCD trip current for pulsating unidirectional current:

    Selected

    current    Measurement

    range    Resolution    Test

    current    Accuracy

    10 mA    4...20,0 mA    0,1 mA    0,35 x IΔn ...2,0 x IΔn    ±10% IΔn

    30 mA    12,0...42,0 mA        0,35xIΔ..1,4xIΔn    

    100 mA    40,0...140 mA    1 mA        

    300 mA    120...420 mA            

    500 mA    200...700 mA            

    ?Capability of measurement for either positive or negative half-periods of forced leakage current

    ?Maximal time of the measurement current flow is 3200 ms

     

    “m.v” - measurement value


    http://yingdian168.cn.b2b168.com